Biological Indicator - Steam Test Cost & Procedure

Biological Indicator - Steam

Biological Indicator - Steam

Book Biological Indicator - Steam Appointment Online Near me at the best price in Delhi/NCR from Ganesh Diagnostic. NABL & NABH Accredited Diagnostic centre and Pathology lab in Delhi offering a wide range of Radiology & Pathology tests. Get Free Ambulance & Free Home Sample collection. 24X7 Hour Open. Call Now at 011-47-444-444 to Book your Biological Indicator - Steam at 50% Discount.

₹ 500 ₹ 250

Request A Call Back

For steam sterilisation operations, Super Fast Self-contained Biological Indicator. Per vial, Geobacillus stearothermophilus 106 spores—hour readout.

After 48 hours of incubation, visual confirmation of the pH colour shift is optional. If the sterilisation treatment is unsuccessful, the culture media would initially turn greenish before becoming yellow during 60 C incubation, indicating the presence of living spores. After pregnancy, the culture medium will still be purple if the sterilisation step is successful.

Several Steam Sterilizers:

  • Process indicators, Type 1
  • Specific-Use Indicators, Type 2.
  • Single-Variable Indicators, Type 3
  • Multivariable indicators, type 4
  • Incorporating indicators is Type 5 (Integrators)
  • Emulating indicators is Type 6 (Cycle Verification Indicators)

Biological Indicators: What Are They?

Biological indicators (BIs), according to ANSI/AAMI and ISO, are test items containing live microorganisms that demonstrate a specific level of resistance to a particular sterilising process.

A biological indicator provides data on whether the conditions were satisfied for a sterilisasterilisation procedure to eliminate a certain number of germs, demonstrating pprocess'sconfidence. Endospores or bacterial spores are the microorganisms most usually used in BIs.

The choice of bacterial spores for a  method also considers the spores' known resistance to that method.

For instance, Geobacillus stearothermophilus spores are used in BIs that monitor these sterilising processes because they are very resistant to steam and vaporised hydrogen peroxide. While mechanical and chemical indicators do not ensure sterilisation, they do aid in identifying operational mistakes (such as overloaded steriliser or improper packaging) and equipment problems. With each steriliser load, mechanical and chemical monitoring should be performed.

Monitoring comprises confirming that the pressure, temperature, and exposure duration have reached the levels advised by the steriliser manufacturer and recording this information in your sterilisation records. This could be the first sign because these characteristics can be seen during the sterilisation cycle.

The procedure for testing biological indicators:

  • A carrier material on which bacterial spores with specific resistance to the sterilising procedure have been put makes up a biological indicator.
  • A glassine bag or a vial is used to contain the carrier substance.
  • To determine if any spores survived the sterilisation procedure, the BI is subjected to the process and then incubated under predetermined growth conditions.
  • If no spores develop, the test is successful.
  • If none survive, the test is invalid if growth is found.
  •  While utilising a biological indicator to check on sterilising operations, Sterile
  • Processing staff should always adhere to the manufacturer's instructions for use (IFUs), regardless of the kind of method or application.

Test Type Biological Indicator - Steam